Climasys CE

Intercambiador de calor

-

Climasys CE
  • Características

    Air-air exchangers
    Specially recommended for installations in which:

    • The ambient temperature is lower than the desired temperature inside the enclosure.
    • A high protection rating is required: IP 54 or IP 55.
    • The outside environment is highly polluted.

    Large range of solutions:

    • 4 models.
    • Two installation versions: top-mounting model and side-mounting model.
    • Cooling power from 15 to 70 W/ºK .
    • According to the input voltage: 230 V (50/60 Hz).

     

    Air-water exchangers
    Specially recommended for installations in which:

    • The ambient temperature is higher than the desired temperature inside the enclosure.
    • The outside environment is corrosive, the internal and external air circuits are independent.
    • The outside environment is highly polluted, the temperature is controlled by cold water without requiring the use of an external air circuit.
    • It is necessary to extract the heat produced by the industrial site.

    Large range of solutions

    • 3 models.
    • Two installation versions: top-mounting model and side-mounting model.
    • Cooling power of 2,100 W and 3,150 W.
    • According to the input voltage: 230 V (50/60 Hz).


    Beneficios

    Guaranteed watertightness!

    Air-air exchangers

    • They have an aluminium-built exchange battery that separates the two air circuits (inside and outside) and stops powder and pollutant atmospheric air from getting inside the enclosure and contaminating it. They do not bring the atmospheres inside and outside the enclosure into contact.
    • Easy maintenance.
    • High IP (IP 54).

    Air-water exchangers

    • The inside temperature of the enclosure does not depend on the outside.
    • They do not bring the atmospheres inside and outside the enclosure into contact.
    • Good performance and minimum maintenance time required.

    Aplicaciones

    Air-air exchangers

    • In highly polluted atmospheres or when large amounts of heat must be evacuated without bringing the outside and inside atmospheres into contact.

    Air-water exchangers
    Specially recommendedin installations where:

    • The ambient temperature inside the enclosure is lower than required
    • When a high IP degree (IP54/IP55) is requested
    • The externel environment is very polluted.
    • The air-water exchangers are recomended in cases when a large amount of heat has to be evacuated and a water cooling installation is available.
    • Particularly suitable for severe and highly pollutant atmospheres, since there is no outside air circuit.
    • The temperature in the enclosure is controlled by means of a thermostat that closes or opens an electro-valve.

    Gallery

    • Air-air exchanger